logo
Produkte
EINZELHEITEN ZU DEN PRODUKTEN
Zu Hause > Produkte >
ZR402G-M-E-E-A-SCT Yokogawa Separater Typ Zirkonoxid-Sauerstoffanalysator-Konverter 4-20mA

ZR402G-M-E-E-A-SCT Yokogawa Separater Typ Zirkonoxid-Sauerstoffanalysator-Konverter 4-20mA

MOQ: 1 Piece
Preis: USD 1200-2500 / Piece
Standardverpackung: Original factory carton with anti-static protection and shock-proof foam, export-grade packaging
Lieferfrist: 3-7 working days for stock items
Zahlungsmethode: T/T,L/C,Western Union,
Lieferkapazität: 200 Pieces per Month
Einzelheiten
Place of Origin
Japan
Markenname
Yokogawa
Zertifizierung
CE, cULus
Model Number
ZR402G-M-E-E-A-SCT
Product Type:
Separate Type Zirconia Oxygen Analyzer (Converter)
Applicable Probe:
ZR22G / ZR202G Separate Type Zirconia Probe
Measuring Range:
0 to 25 vol% O2 standard, 0.01 to 100 vol% O2 selectable
Output Signal:
Two isolated 4-20 mA DC outputs, max load 550 Ohm
Digital Communication:
HART 7 protocol (optional)
Accuracy:
+/-1% FS
Repeatability:
+/-0.5% FS
Response Time:
Within 5 s (90% response)
Power Supply:
100-240 V AC, 50/60 Hz / 24 V DC
Power Consumption:
Approx. 100 VA
Ambient Temperature:
-20 to 55 C
Structure:
IP65 / NEMA 4X, panel and wall mount
Display:
LCD with backlight and integrated keys
Weight:
Approx. 4 kg
Application:
Boiler, furnace, cement kiln, refinery and incineration combustion control
Hervorheben:

Yokogawa Zirkonoxid-Sauerstoffanalysator-Konverter

,

Separater Sauerstoffanalysator 4-20mA

,

ZR402G Sauerstoffanalysator mit Garantie

Beschreibung des Produkts
Yokogawa Prozessanalysator

ZR402G-M-E-E-A-SCT Yokogawa Zirkonoxid-Sauerstoffanalysator mit getrennter Bauform, Konverter 4-20mA

Konvertereinheit kompatibel mit Sonden mit getrennter Bauform ZR22G / ZR202G · Zwei isolierte 4-20 mA DC-Ausgänge
Schnelle Reaktion
90% Ansprechen innerhalb von 5 Sekunden für Echtzeit-Verbrennungsregelung
Doppelter Ausgang
Zwei isolierte 4-20 mA DC-Ausgänge mit wählbaren Bereichen
Robustes Design
IP65 / NEMA 4X Gehäuse für raue Anlagenumgebungen

Produktübersicht

Der Yokogawa ZR402G ist ein Konverter für Zirkonoxid-Sauerstoffanalysatoren mit getrennter Bauform, der für die kontinuierliche Messung der Sauerstoffkonzentration in Abgasen und industriellen Prozessgasen entwickelt wurde. Gekoppelt mit einer Zirkonoxidsonde ZR22G oder ZR202G liefert er stabile, hochgenaue O2-Messwerte, die den Betreibern helfen, die Verbrennungseffizienz zu optimieren, den Kraftstoffverbrauch zu senken und die Emissionen zu reduzieren.

Modell ZR402G-M-E-E-A-SCT wird werkseitig mit doppelten Stromausgängen, einem hintergrundbeleuchteten LCD mit integrierter Bedienerschnittstelle und optionaler HART-Kommunikation für die nahtlose Integration in DCS- und SPS-Steuerungssysteme konfiguriert.

Hauptmerkmale

  • Die Konfiguration mit getrennter Bauform hält den Konverter an einem sicheren, zugänglichen Ort, während die Sonde im Rauchfang oder Ofen arbeitet.
  • Zirkonoxid-Sensortechnologie mit langer Lebensdauer und minimalem Drift für geringe Wartungskosten.
  • Zwei isolierte 4-20 mA DC-Ausgänge, jeder mit frei zuordenbaren Messbereichen.
  • HART 7 digitale Kommunikation für Fernkonfiguration und Diagnose.
  • Selbstdiagnosefunktionen, Sensorfehlermeldung und Kalibrierungshistorie für zuverlässigen Betrieb.
  • Einfache Ein-Tasten-Kalibrierung mit Instrumentenluft als Referenzgas.

Technische Spezifikationen

Parameter Spezifikation
Produkttyp Zirkonoxid-Sauerstoffanalysator mit getrennter Bauform (Konvertereinheit)
Anwendbare Sonde Zirkonoxidsonde mit getrennter Bauform ZR22G / ZR202G
Messbereich 0 bis 25 Vol.-% O2 Standard; 0,01 bis 100 Vol.-% O2 wählbar
Ausgangssignal Zwei isolierte 4-20 mA DC-Ausgänge, max. Last 550 Ω
Digitale Kommunikation HART 7 Protokoll (optional)
Genauigkeit ±1% FS
Wiederholgenauigkeit ±0,5% FS
Reaktionszeit Innerhalb von 5 s (90% Ansprechen)
Stromversorgung 100-240 V AC, 50/60 Hz / 24 V DC
Stromverbrauch Ca. 100 VA
Umgebungstemperatur -20 bis 55 °C
Struktur IP65 / NEMA 4X, Schalttafeleinbau und Wandmontage
Anzeige LCD mit Hintergrundbeleuchtung und integrierten Tasten
Referenzgas Instrumentenluft (Umgebungsluft)
Gewicht Ca. 4 kg

Typische Anwendungen

  • Überwachung der Verbrennungseffizienz von Kesseln und Öfen
  • Regelung von Zementöfen, Glasöfen und metallurgischen Öfen
  • Messung von Prozessgasen in Raffinerien und petrochemischen Anlagen
  • Abfallverbrennungs- und Emissionsüberwachungssysteme

Bestellinformationen

Modell: ZR402G-M-E-E-A-SCT — Zirkonoxid-Sauerstoffanalysator-Konverter mit getrennter Bauform. Sonden, Sondenschutz und Kalibrierzubehör sind separat erhältlich. Bitte bestätigen Sie die vollständige Konfiguration und den Suffixcode vor der Bestellung.

Benötigen Sie Preise oder ein vollständiges Angebot?
Senden Sie uns Ihre erforderliche Konfiguration, Menge und Lieferziel — unsere Ingenieure werden mit einem maßgeschneiderten Angebot und Lieferzeit antworten.
Produkte
EINZELHEITEN ZU DEN PRODUKTEN
ZR402G-M-E-E-A-SCT Yokogawa Separater Typ Zirkonoxid-Sauerstoffanalysator-Konverter 4-20mA
MOQ: 1 Piece
Preis: USD 1200-2500 / Piece
Standardverpackung: Original factory carton with anti-static protection and shock-proof foam, export-grade packaging
Lieferfrist: 3-7 working days for stock items
Zahlungsmethode: T/T,L/C,Western Union,
Lieferkapazität: 200 Pieces per Month
Einzelheiten
Place of Origin
Japan
Markenname
Yokogawa
Zertifizierung
CE, cULus
Model Number
ZR402G-M-E-E-A-SCT
Product Type:
Separate Type Zirconia Oxygen Analyzer (Converter)
Applicable Probe:
ZR22G / ZR202G Separate Type Zirconia Probe
Measuring Range:
0 to 25 vol% O2 standard, 0.01 to 100 vol% O2 selectable
Output Signal:
Two isolated 4-20 mA DC outputs, max load 550 Ohm
Digital Communication:
HART 7 protocol (optional)
Accuracy:
+/-1% FS
Repeatability:
+/-0.5% FS
Response Time:
Within 5 s (90% response)
Power Supply:
100-240 V AC, 50/60 Hz / 24 V DC
Power Consumption:
Approx. 100 VA
Ambient Temperature:
-20 to 55 C
Structure:
IP65 / NEMA 4X, panel and wall mount
Display:
LCD with backlight and integrated keys
Weight:
Approx. 4 kg
Application:
Boiler, furnace, cement kiln, refinery and incineration combustion control
Minimum Order Quantity:
1 Piece
Preis:
USD 1200-2500 / Piece
Packaging Details:
Original factory carton with anti-static protection and shock-proof foam, export-grade packaging
Delivery Time:
3-7 working days for stock items
Payment Terms:
T/T,L/C,Western Union,
Supply Ability:
200 Pieces per Month
Hervorheben

Yokogawa Zirkonoxid-Sauerstoffanalysator-Konverter

,

Separater Sauerstoffanalysator 4-20mA

,

ZR402G Sauerstoffanalysator mit Garantie

Beschreibung des Produkts
Yokogawa Prozessanalysator

ZR402G-M-E-E-A-SCT Yokogawa Zirkonoxid-Sauerstoffanalysator mit getrennter Bauform, Konverter 4-20mA

Konvertereinheit kompatibel mit Sonden mit getrennter Bauform ZR22G / ZR202G · Zwei isolierte 4-20 mA DC-Ausgänge
Schnelle Reaktion
90% Ansprechen innerhalb von 5 Sekunden für Echtzeit-Verbrennungsregelung
Doppelter Ausgang
Zwei isolierte 4-20 mA DC-Ausgänge mit wählbaren Bereichen
Robustes Design
IP65 / NEMA 4X Gehäuse für raue Anlagenumgebungen

Produktübersicht

Der Yokogawa ZR402G ist ein Konverter für Zirkonoxid-Sauerstoffanalysatoren mit getrennter Bauform, der für die kontinuierliche Messung der Sauerstoffkonzentration in Abgasen und industriellen Prozessgasen entwickelt wurde. Gekoppelt mit einer Zirkonoxidsonde ZR22G oder ZR202G liefert er stabile, hochgenaue O2-Messwerte, die den Betreibern helfen, die Verbrennungseffizienz zu optimieren, den Kraftstoffverbrauch zu senken und die Emissionen zu reduzieren.

Modell ZR402G-M-E-E-A-SCT wird werkseitig mit doppelten Stromausgängen, einem hintergrundbeleuchteten LCD mit integrierter Bedienerschnittstelle und optionaler HART-Kommunikation für die nahtlose Integration in DCS- und SPS-Steuerungssysteme konfiguriert.

Hauptmerkmale

  • Die Konfiguration mit getrennter Bauform hält den Konverter an einem sicheren, zugänglichen Ort, während die Sonde im Rauchfang oder Ofen arbeitet.
  • Zirkonoxid-Sensortechnologie mit langer Lebensdauer und minimalem Drift für geringe Wartungskosten.
  • Zwei isolierte 4-20 mA DC-Ausgänge, jeder mit frei zuordenbaren Messbereichen.
  • HART 7 digitale Kommunikation für Fernkonfiguration und Diagnose.
  • Selbstdiagnosefunktionen, Sensorfehlermeldung und Kalibrierungshistorie für zuverlässigen Betrieb.
  • Einfache Ein-Tasten-Kalibrierung mit Instrumentenluft als Referenzgas.

Technische Spezifikationen

Parameter Spezifikation
Produkttyp Zirkonoxid-Sauerstoffanalysator mit getrennter Bauform (Konvertereinheit)
Anwendbare Sonde Zirkonoxidsonde mit getrennter Bauform ZR22G / ZR202G
Messbereich 0 bis 25 Vol.-% O2 Standard; 0,01 bis 100 Vol.-% O2 wählbar
Ausgangssignal Zwei isolierte 4-20 mA DC-Ausgänge, max. Last 550 Ω
Digitale Kommunikation HART 7 Protokoll (optional)
Genauigkeit ±1% FS
Wiederholgenauigkeit ±0,5% FS
Reaktionszeit Innerhalb von 5 s (90% Ansprechen)
Stromversorgung 100-240 V AC, 50/60 Hz / 24 V DC
Stromverbrauch Ca. 100 VA
Umgebungstemperatur -20 bis 55 °C
Struktur IP65 / NEMA 4X, Schalttafeleinbau und Wandmontage
Anzeige LCD mit Hintergrundbeleuchtung und integrierten Tasten
Referenzgas Instrumentenluft (Umgebungsluft)
Gewicht Ca. 4 kg

Typische Anwendungen

  • Überwachung der Verbrennungseffizienz von Kesseln und Öfen
  • Regelung von Zementöfen, Glasöfen und metallurgischen Öfen
  • Messung von Prozessgasen in Raffinerien und petrochemischen Anlagen
  • Abfallverbrennungs- und Emissionsüberwachungssysteme

Bestellinformationen

Modell: ZR402G-M-E-E-A-SCT — Zirkonoxid-Sauerstoffanalysator-Konverter mit getrennter Bauform. Sonden, Sondenschutz und Kalibrierzubehör sind separat erhältlich. Bitte bestätigen Sie die vollständige Konfiguration und den Suffixcode vor der Bestellung.

Benötigen Sie Preise oder ein vollständiges Angebot?
Senden Sie uns Ihre erforderliche Konfiguration, Menge und Lieferziel — unsere Ingenieure werden mit einem maßgeschneiderten Angebot und Lieferzeit antworten.
Sitemap |  Datenschutzrichtlinie | China gut Qualität GE Bently Nevada Lieferant. Urheberrecht © 2021-2026 GREAT SYSTEM INDUSTRY CO. LTD - Alle. Alle Rechte vorbehalten.